Menu
Your Cart
Launch ES200 EV battery insulation resistance indicator
Launch ES200 EV battery insulation resistance indicator
Launch ES200 EV battery insulation resistance indicator
Launch ES200 EV battery insulation resistance indicator
Launch ES200 EV battery insulation resistance indicator
Launch ES200 EV battery insulation resistance indicator
Launch ES200 EV battery insulation resistance indicator

Launch ES200 EV battery insulation resistance indicator

  • SKU: BD17748
999.00 €

Prices shown include tax

Send Message

Description

Launch ES200 EV battery insulation resistance indicator
Features:
  • The ES 200 can be used to measure the insulation resistance of the HV lines to the vehicle body - for this, each HV line is simply tested against the vehicle body.
  • The ES200 can be used as a stand-alone unit or connected to the TAB 3. With the TAB 3 it can be controlled via Bluetooth and a measurement protocol can be saved after the test.
  • During the measurement, a very high test voltage is applied, the resulting current flow provides information about the insulation resistance.
  • Voltage range between 500-5000V possible - The applied test voltage varies from manufacturer to manufacturer - The test voltage should be at least as high as the operating voltage of the vehicle.
  • With its 5-inch colour screen, it is easy to read even in sunlight.
  • It is equipped with three measuring modes: Time measurement, comparison and continuous measurement.
Example of a measurement report:

Varžos testavimo rezultatai

Technical parameters:
  • Battery: 3150 mAh
  • Screen: 5" inches
  • Operating temperature: 0 °C - +50 °C
  • Dimensions: 180 x 174 x 65 mm
  • Weight: 1.7 kg
DC voltage testing parameters:
  • Voltage: 30 - 600 V
  • Value range: 1 V
  • Testing accuracy: +/- 3%
AC voltage testing parameters:
  • Voltage: 30 - 600 V (50 / 60 Hz)
  • Value range: 1 V
  • Testing accuracy: +/- 3%
Test results parameters:
  • Test voltage: 500V | 1000V | 2000V | 5000V
  • Measuring ranges: 0MΩ - 20MΩ | 0MΩ - 40GΩ | 0MΩ - 100GΩ | 0MΩ - 1000GΩ
  • Open circuit voltage: DC 500V | DC 1000V | DC 2000V | DC 5000V
  • Accuracy of measurements:

0MΩ - 99.9MΩ (+/- 3% +5); 100MΩ - 9.99GΩ (+/- 5% +5); 10GΩ - 20GΩ (+/- 10% +5) |

0MΩ - 99.9MΩ (+/- 3% +5); 100MΩ - 9.99GΩ (+/- 5% +5); 10GΩ - 40GΩ (+/- 10% +5) |

0MΩ - 99.9MΩ (+/- 3% +5); 100MΩ - 9.99GΩ (+/- 5% +5); 10GΩ - 100GΩ (+/- 10% +5) |

0MΩ - 99.9MΩ (+/- 3% +5); 100MΩ - 9.99GΩ (+/- 5% +5); 10GΩ - 1000GΩ (+/- 10% +5) |

  • Short-circuit current: <3.0 mA