Menu
Your Cart
Oscilloscope and multimeter for electric vehicles Launch EM101N EV
Oscilloscope and multimeter for electric vehicles Launch EM101N EV
Oscilloscope and multimeter for electric vehicles Launch EM101N EV
Oscilloscope and multimeter for electric vehicles Launch EM101N EV
Oscilloscope and multimeter for electric vehicles Launch EM101N EV

Oscilloscope and multimeter for electric vehicles Launch EM101N EV

  • SKU: BD17747
799.00 €

Prices shown include tax

Send Message

Description

Oscilloscope and multimeter for electric vehicles Launch EM101N EV
Features:
  • 2-channel oscilloscope with multimeter function 
  • Brand-new diagnostic APP with friendly interface, convenient and easy use, which supports local saving and opening of waveforms. 
  • Supports both wired connection and wireless connection with supported X-431 diagnostic tools. The brand-new UI style design supports three display modes, which can be freely selected and switched at will.
  • Rich accessories, pricker sets, multimeter pens, crocodile clips, oscilloscope channel test lines, etc. 
  • It is equipped with a 3.1 Ah battery and can also be used wirelessly.
Parameters: 
Multimeter:
  • DC voltage: automatic limit setting, limits +- 600V
  • AC voltage: automatic limit setting, limits +- 600V
  • DC electric current: automatic limit setting, limits +- 10A. (If there is a need to measure a higher electric current, it is necessary to connect an additional accessory)
  • AC electric current: automatic limit setting, limits +- 10A. (If there is a need to measure a higher electric current, it is necessary to connect an additional accessory)
  • Impedance: automatic limit setting, limits 0 ~ 6MΩ
  • On/off: Tweet when resistance is lower than 30Ω
  • Diode: 0.5V – 2.0V
Oscilloscope:
  • Number of channels: 2 analog channels
  • Real-time testing frequency: 50 MHz/s
  • Time steps: 1 us/div ~ 10 s/div, in steps of 1 ~ 2 ~ 5 times
  • Test modes: normal, peak setting, average
  • Memory size: 1M
  • Input connection: DC, AC, ground
  • Input resistance: 1 MΩ ±2% in parallel with 15pF ± 5pF
  • Vertical sensitivity: 2mV/div ~ 5V/div
  • Vertical resolution: 8 bits
  • Maximum input voltage: 40V (AC+DC peak values)
  • Probe attenuation factor: 1x; 10x; 100x
  • Excitation types: threshold, pulse width excitation
  • Excitation mode: automatic, normal, individual
  • Automatic measurements: peak values, average value, maximum value, minimum value, highest value, lowest value, frequency and period